Electrosurgical pencil, 70mm, 2 buttons, 3 meters cable, 3 prong connector

In stock
Product code 0604
€2.69 €2.26
Description
The electrosurgical pencil, cutting & cauterizing, two switches, cable 3 m, 3-prong connector, blade 70 mm, is used in all hospital departments, clinics, including intensive care units and ambulance services to cut tissue during surgical operation. Characteristics: • Sterility can only be guaranteed if the expiration date has not passed and the package is not damaged. • This device is for single-patient use only. • The grounding pad must be applied to the patient before using the ESU pencil for the surgery. • Put the pencil in a safe place and keep it isolated from the patient when it is temporarily unused. • Use the pencil immediately after opening the package. • Wear suitable protective equipment. Never return contaminated material to its original container. Do not eat, drink, or smoke when using this product. Wash thoroughly after handling. Product specifications: a. Frequency field: 0MH z̴ 1.0MHz; b. Maximum current flow: 1A; c. Cable length: 3m; d. Load impedance: non-electric impedance resistance - 200Ώ; e. The electrode adopts stainless steel materials connecting the sleeve and the covering knife - ABS plastic resin, the Cable - flexible PVC wire; f. The cable supports a pulling force of 20N, and lasts 15s without disconnection; g. Between the electrode and the covering knife, it can support 50HZ alternating current, 2500v sinusoidal voltage, and lasts 1min without infiltration; h. The cable insulation can support 50HZ, 3000V sinusoidal voltage, lasts 1 min without infiltration; i. The cable withstands the test of 1.5v in an open circuit connected to surgical frequency devices, and lasts 30s without infiltration; j. The safe biocompatibility of the electrode complies with the requirements of the ISO 10993 series; k. The conductive part of the electrode is isolated from the tail, and the insulating material makes the sleeve. Instructions of use: 1. Insert the plug of the pencil into the electrosurgical generator. Remove the protective sleeve from the electrode. 2. Make sure the electrode is well fixed. 3. Check the yellow & blue button switch is working well. 4. The yellow button is used for cutting (CUT). The blue button is used for coagulation (COAG). 5. After the operation, shut down the power and drop it into the garbage bin.
Specifications
More Information
Length 30
Width 11
Height 1
MPN 0604
Add a review
Write Your Own Review
You're reviewing:Electrosurgical pencil, 70mm, 2 buttons, 3 meters cable, 3 prong connector